Home About Dorner Contact Us Distributors Tradeshows Site Map

 
Dorner Performance Newsletter


 

DORNER MFG. CORP.
975 Cottonwood Ave
P.O. Box 20
Hartland, WI 53029 USA

INSIDE THE USA
TEL: 800.397.8664
FAX: 800.369.2440

OUTSIDE THE USA
TEL: 262.367.7600
FAX: 262.367.5827

Home > Standard Products > 2200 Series > Flat Belt End Drive

3200 SERIES CONVEYORS: Gearmotors




For gearmotor selection steps, view the Gearmotor Mounting Package Section

Gearmotor Accessories


90˚ Gearmotor Heat Sink


  • Reduces gear head surface
    temperature by up to 50˚ (10˚C)
  • Compatible with Light and
    Standard Load 90˚ Gearmotors
  • Black anodized aluminum
Part Number
Description
694025 90?˚ Gearmotor Heat Sink



Light Load, Fixed Speed (For use on End Drive Conveyor Only)


CHART 1

90˚


  • Sealed Gearmotor
  • NEMA 42 CZ C Face
    Totally enclosed, Fan cooled.
  • 115V 1 phase includes switch, Cord & Overload protection
  • 208-230/460V 3 phase wiring by others
  • 60 Hz
  • Order 3 phase starter separately, See page 116
Part Number RPM Gearmotor
Type
1 Phase 3 Phase In-lbs N-m Starter
Chart
Hp Kw FLA Hp Kw FLA
32M060HL4(vp)F(n˚)
32M040HL4(vp)F(n)
32M020HL4(vp)F(n)
32M010HL4(vp)F(n)
29
43
86
173
L
L
L
L
0.25
0.25
0.25
0.25
0.19
0.19
0.19
0.19
5
5
5
5
0.25
0.25
0.25
0.25
0.19
0.19
0.19
0.19
1.2/0.6
1.2/0.6
1.2/0.6
1.2/0.6
226
237
142
78
25.5
26.8
16
18.8
L
L
L
L
(vp) = Voltage and Phase
11 = 115V, 1 phase
23 = 208 - 230 / 460V, 3 phase
(n) = Reversing Capability
N = No reversing switch.
R = With reversing switch (115V, 1 phase only)


CHART 2

90˚


  • Sealed Gearmotor
  • Totally enclosed, Fan cooled.
  • IEC 63 B5 C Face
  • IP 55 Protection Rating
  • 50 Hz
  • Order starter separately, See page 116
Part Number RPM Gearmotor Type 1 Phase 3 Phase N-m Starter
Chart
Kw FLA Kw FLA
62Z060HS4(vp)FN
62Z040HS4(vp)FN
62Z020HS4(vp)FN
62Z010HS4(vp)FN
62Z005HS4(vp)FN
23
35
70
140
280
L
L
L
L
L
0.18
0.18
0.18
0.18
0.18
1.6
1.6
1.6
1.6
1.6
0.18
0.18
0.18
0.18
0.18
1.4/.8
1.4/.8
1.4/.8
1.4/.8
1.4/.8
26.4
28.9
19.4
10.7
5.6
I
I
I
I
I
(vp) = Voltage and Phase
21 = 230V, 1 phase
23 = 230, 3 phase
43 = 400V, 3 phase
Note: When buying a gearmotor only without the starter, the customer must supply their own on/off switch and motor overload protection to comply with the CE Safety Directive.

 

Light Load, Variable Speed (For use on End Drive Conveyor Only)



CHART 3

90˚


  • 130 Volts DC
  • NEMA 42 CZ C Face
  • Totally enclosed, Fan cooled
  • 300 - 2500 RPM motor
  • Order controller separately, See pages 114 & 115
Part Number RPM Gearmotor
Type
Hp Kw FLA In-lbs N-m Vari - Speed
Control Chart
22M060HSD3DEN
22M040HSD3DEN
22M020HSD3DEN
22M010HSD3DEN
42
63
125
250
L
L
L
L
0.33
0.33
0.33
0.33
0.25
0.25
0.25
0.25
2.3
2.3
2.3
2.3
198
163
98
54
22.4
18.4
11.1
6.1
A
A
A
A


CHART 4

90˚


  • Variable Frequency Drive, 6 - 60 Hz
  • Sealed Gearmotor
  • NEMA 56C C Face
  • Totally enclosed, Fan cooled
  • 230/460 Volts, 3 phase
  • Order controller separately, See pages 114 & 115
Part Number RPM Gearmotor
Type
Hp Kw FLA In-lbs N-m Vari- Speed
Control Chart
32M060HL423EN
32M040HL423EN
32M020HL423EN
32M010HL423EN
32M005HL423EN
29
43
86
173
345
L
L
L
L
L
0.25
0.25
0.25
0.25
0.25
0.19
0.19
0.19
0.19
0.19
1.6 /.97
1.6 /.97
1.6 /.97
1.6 /.97
1.6 /.97
226
237
142
78
41
25.5
86.8
16
8.8
4.6
D and E
D and E
D and E
D and E
D and E


CHART 5

90˚


  • Variable Frequency Drive, 25 - 63 Hz
  • Sealed Gearmotor
  • IEC 63 B5 C Face
  • IP 55 Protection Rating
  • Totally enclosed, Fan cooled
  • 230V 3 phase
  • Order controller separately, See pages
    114 & 115
Part Number RPM Gearmotor Type 3 Phase N-m Vari- Speed
Control Chart
Kw FLA
62Z060HS423EN
62Z040HS423EN
62Z020HS423EN
62Z010HS423EN
23
35
70
140
L
L
L
L
0.18
0.18
0.18
0.18
1.4
1.4
1.4
1.4
26.4
28.9
19.4
10.7
BBBB
At 50 Hz
Note: When buying a gearmotor only without the starter, the customer must supply their own on/off switch and motor overload protection to comply with the CE Safety Directive.

 

Standard Load, Fixed Speed (For use on End Drive Conveyor Only)


CHART 6

90˚


  • Sealed Gearmotors
  • NEMA 56 C Face
  • Totally enclosed, Fan cooled
  • 115V 1 phase includes switch, Cord & Overload protection
  • 208-230/460V 3 phase wiring by others
  • 60 Hz
  • Order 3 phase starter separately, See page 116
Part Number RPM Gearmotor Type 1 Phase 3 Phase in-lbs N-m Vari- Speed
Control Chart
Hp Kw FLA Hp Kw FLA
32M060HS4(vp)F(n)
32M040HS4(vp)F(n)
32M020HS4(vp)F(n)
32M010HS4(vp)F(n)
32M005HS4(vp)F(n)
29
43
86
173
345
S
S
S
S
S
0.5
0.5
0.5
0.5
0.5
0.37
0.37
0.37
0.37
0.37
7.4
7.4
7.4
7.4
7.4
0.5
0.5
0.5
0.5
0.5
0.37
0.37
0.37
0.37
0.37
2.1-2/1
2.1-2/1
2.1-2/1
2.1-2/1
2.1-2/1
226
247
248
156
81
25.5
27.9
27.9
17.6
9.1
M
M
M
M
M
(vp) = Voltage and Phase
11 = 115V, 1 phase
23 = 208 - 230 / 460V, 3 phase
(n) = Reversing Capability
N = No reversing switch.
R = With reversing switch
(115V, 1 phase only)

CHART 7

Parallel Shaft


  • Sealed Gearmotor
  • Totally enclosed, Fan cooled
  • 115V 1 phase includes switch, Cord & Overload protection
  • 230V 3 phase wiring by others
  • 60 Hz
  • Order 3 phase starter separately, See page 116
Part Number RPM Gearmotor Type 1 Phase 3 Phase in-lbs N-m Vari- Speed
Control Chart
Hp Kw FLA Hp Kw FLA
62M180PS4(vp)F(n)
62M060PS4(vp)F(n)
(x)2M030PS4(vp)F(n)
(x)2M020PS4(vp)F(n)
(x)2M010PS4(vp)F(n)
(x)2M005PS4(vp)F(n)
10
29
58
86
173
345
S
S
S
S
S
S
0.08
0.17
0.33
0.33
0.33
0.33
0.06
0.13
0.25
0.25
0.25
0.25
1.2
1.9
4
4
4
4
.17
.17
.38
.38
.38
.38
0.13
0.13
0.28
0.28
0.28
0.28
1.0
1.0
1.9
1.9
1.9
1.9
341
270
250
167
108
56
38.5
30.5
28.3
18.9
12.2
6.3
L
L
M
M
M
M

 

(vp) = Voltage and Phase
11 = 115V, 1 phase
23 = 230 V, 3 phase
(n) = Reversing Capability
N = No reversing switch.
R = With reversing switch (115V, 1 phase only)
(x) = 3 for 1 phase, 6 for 3 phase

CHART 8

90˚


  • Sealed Gearmotor
  • IEC 71 B5 C Face
  • IP55 Protection Rating
  • Totally enclosed, Fan cooled
  • Non-reversible
  • 50 Hz
  • Order starter separately, See page 116
Part Number RPM Gearmotor Type 1 Phase 3 Phase In-lbs N-m Vari - Speed
Control Chart
Kw FLA Kw FLA
32Z060HS4(vp)FN
32Z040HS4(vp)FN
32Z020HS4(vp)FN
32Z010HS4(vp)FN
32Z005HS4(vp)FN
23
35
70
140
280
S
S
S
S
S
0.37
0.37
0.37
0.37
0.37
2.6
2.6
2.6
2.6
2.6
0.37
0.37
0.37
0.37
0.37
2.1/1.2
2.1/1.2
2.1/1.2
2.1/1.2
2.1/1.2
226
237
142
78
41
26.8
29.4
29.9
21.5
11.2
J
J
J
J
J
(vp) = Voltage and Phase
21 = 230V, 1 phase
23 = 230/460V, 3 phase
43 = 400,V 3 phase
Note: When buying a gearmotor only without the starter, the customer must supply their own on/off switch and motor overload protection to comply with the CE Safety Directive.

 

Standard Load, Variable Speed (For use on End Drive Conveyor Only)


CHART 9

90˚


  • 90V DC
  • Sealed Gearmotor
  • NEMA 56 C Face
  • Totally enclosed, Fan cooled
  • Order controller separately, See pages 114 & 115
Part Number RPM Gearmotor Type Hp Kw FLA in-lbs N-m Vari- Speed
Control Chart
62Z060HS423EN
62Z040HS423EN
62Z020HS423EN
62Z010HS423EN
62Z005HS423EN
42
63
125
250
500
S
S
S
S
S
0.5
0.5
0.5
0.75
0.75
0.37
0.37
0.37
0.5
0.5
5
5
5
7.5
7.5
198
215
196
108
56
22.4
24.3
22.1
12.2
6.3
C
C
C
C
C

CHART 10

90˚


  • 130 Volts DC
  • Sealed Gearmotor
  • Totally enclosed, Non-ventilated
  • 300 - 2500 RPM motor
  • Order controller separately, See page 36
Part Number RPM Gearmotor Type Hp Kw FLA in-lbs N-m Vari - Speed
Control Chart
62M180PSD3DEN
62M060PSD3DEN
62M030PSD3DEN
62M020PSD3DEN
62M010PSD3DEN
62M005PSD3DEN
14
42
83
125
250
500
S
S
S
S
S
S
0.12
0.25
0.25
0.25
0.33
0.25
0.09
0.19
0.19
0.19
0.25
0.19
1
1.8
1.8
1.8
2.3
1.8
341
270
135
90
72
25
38.5
30.5
15.3
10.2
8.1
2.
A
A
A
A
A
A


CHART 11

90˚


  • Variable Frequency drive, 25 - 63 Hz
  • Sealed Gearmotor
  • IEC 71 B5 C Face
  • IP 55 Protection Rating
  • Totally enclosed, Fan cooled
  • 230 Volts, 3 Phase
  • Order controller separately, See pages 114 & 115
Part Number *RPM Gearmotor Type 3 Phase N-m Vari - Speed
Control Chart
Kw FLA
32Z060HS423EN
32Z040HS423EN
32Z020HS423EN
32Z010HS423EN
32Z005HS423EN
23
35
70
140
280
S
S
S
S
S
0.37
0.37
0.37
0.37
0.37
2.1
2.1
2.1
2.1
2.1
26.8
29.4
29.9
21.5
11.2
B
B
B
B
B
* = At 50 Hz
Note: When buying a gearmotor only without the starter, the customer must supply their own on/off switch and motor overload protection to comply with the CE Safety Directive.


Standard Load, Variable Speed (For use on End Drive Conveyor Only)


CHART 12

Parallel Shaft


  • 130 Volts DC
  • Sealed Gearmotor
  • Totally enclosed, Non-ventilated
  • 300 - 2500 RPM motor
  • Order controller separately, See pages 114 & 115
Part Number RPM Gearmotor Type Hp Kw FLA in-lbs N-m Vari- Speed
Control Chart
62M180PSD3DEN
62M060PSD3DEN
62M030PSD3DEN
62M020PSD3DEN
62M010PSD3DEN
14
42
83
125
250
S
S
S
S
S
0.12
0.25
0.25
0.25
0.33
0.09
0.19
0.19
0.19
0.25
1
1.8
1.8
1.8
2.3
341
270
135
90
72
38.5
30.5
15.3
10.2
8.1
A
A
A
A
A

CHART 13

Parallel Shaft


  • Variable Frequency Drive, 10 to 60 Hz
  • Sealed Gearmotor
  • Totally enclosed, Fan cooled
  • 230 Volts / 3 Phase, VFD duty
  • Order controller separately, See pages 114 & 115
Part Number RPM Gearmotor
Type
Hp Kw FLA in-lbs N-m Vari- Speed
Control Chart
62M180PS423EN
62M060PS423EN
62M030PS423EN
62M020PS423EN
62M010PS423EN
62M005PS423EN
10
29
58
86
173
345
S
S
S
S
S
S
0.17
0.17
0.38
0.38
0.38
0.38
0.13
0.13
0.28
0.28
0.28
0.28
1.0
1.0
1.9
1.9
1.9
1.9
341
270
250
167
115
58
38.5
30.5
28.3
18.9
13
6.5
D and E
D and E
D and E
D and E
D and E
D and E


CHART 14

90˚


  • Integrated motor control
  • Variable Frequency drive, 10 to 80 Hz
  • Digital display with start/stop and
    forward/reverse keypad
  • NEMA 56 C face sealed gearmotorTotally enclosed, Fan cooled
  • 115/230 Volts, 1 Phase input voltage
Part Number *RPM Gearmotor
Type
Hp Kw Controller
Amps
in-lbs Vari- Speed
Control Chart
32M060HS411EC
32M040HS411EC
32M020HS411EC
32M010HS411EC
32M005HH411EC
29
43
86
173
345
H
H
H
H
H
0.5
0.5
0.5
0.5
1.0
0.37
0.37
0.37
0.37
0.74
12.4/6.2
12.4/6.2
12.4/6.2
12.4/6.2
12.4/6.2
226
247
248
156
162
25.5
27.9
27.9
17.6
18.2

* = At 60 Hz



Heavy Load, Fixed Speed



CHART 15

90˚#BFB88F


  • NEMA 56 C Face for .5 & 1 Hp
  • NEMA 143TC C Face for 1.5 Hp
  • NEMA 145TC C Face for 2 Hp (New!)
  • Totally enclosed, Fan cooled
  • 115V, 1 Phase includes switch, cord & overload protection
  • 208 - 230/460 V, 3 Phase wiring by others
  • 60 Hz
  • Order 3 phase starter separately, See page 116
Part Number RPM Gearmotor Type 1 Phase 3 Phase In-lbs N-m Vari - Speed
Control Chart
Hp Kw FLA Hp Kw FLA
32M100HH4(vp)F(N)
32M080HH4(vp)F(N)
32M060HH4(vp)F(N)
32M050HH423FN
32M040HH423FN
32M030HH423FN
32M025HH423FN
32M020HH423FN
32M015HH423FN
32M010HH423FN
32M008HH423FN
17
22
29
35
43
58
70
86
115
173
230
H
H
H
H
H
H
H
H
H
H
H
0.5
0.5
0.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.37
0.37
0.37
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.5
0.5
0.5
1.0
1.0
1.5
1.5
2.0
2.0
2.0
2.0
0.5
0.5
0.5
1.0
1.0
1.5
1.5
2.0
2.0
2.0
2.0
0.37
0.37
0.37
0.74
0.74
1.11
1.11
1.49
1.49
1.49
1.49
2/1
2/1
2/1
3.4/1.7
3.4/1.7
5.0/2.5
5.0/2.5
6.2/3.1
6.2/3.1
6.2/3.1
6.2/3.1
913
833
679
1205
1023
1216
1068
1183
909
636
482
103
94
76
136
115
137
121
134
103
72
54
M
M
M
P
P
˚
˚
˚
˚
˚
˚
(vp) = Voltage and Phase
(N) = No reversing switch
11 = 115V, 1 phase
23 = 230/460V, 3 phase

CHART 16

90˚


  • Sealed Gearmotor
  • IEC 71 B5 C Face for .37 Kw
  • IEC 80 B5 C Face for .55 Kw
  • IEC 90 B5 C Face for 1.1 Kw
  • IP55 Protection Rating
  • Totally enclosed, Fan cooled
  • 50 Hz
  • Order starter separately, See page 116
Part Number RPM* Gearmotor Type 3 Phase N-m Starter Chart
Hp Kw
32Z100HH4(vp)FN
32Z045HH4(vp)FN
32Z030HH4(vp)FN
32Z015HH4(vp)FN
32Z007HH4(vp)FN
14
31
47
93
200
H
H
H
H
H
0.37
0.55
0.55
1.1
1.1
2.1/1.2
2.6/1.5
2.6/1.5
4.7/2.7
4.7/2.7
113
110
81
92
46
J
R
R
K
K
(vp) = Voltage and Phase
23 = 230V, 3 phase
43 = 400V, 3 phase
Note: When buying a gearmotor only without the starter, the customer must supply their own on/off switch and motor overload protection to comply with the CE Safety Directive.


Heavy Load, Variable Speed



CHART 17

90˚


  • Variable Frequency Drive, 6 - 60 Hz
  • NEMA 56 C Face for .5 Hp + 1 Hp
  • NEMA 145TC C Face for 1.5 + 2 Hp
  • Totally enclosed, Fan cooled
  • 230/460V, 3 phase
  • Order controller separately, See pages 114 & 115
Part Number RPM Gearmotor Type Hp Kw FLA In-lbs N-m Vari - Speed
Control Chart
32M100HH423EN
32M080HH423EN
32M060HH423EN
32M050HH423EN
32M040HH423EN
32M030HH423EN
32M025HH423EN
32M020HH423EN
32M015HH423EN
32M010HH423EN
32M008HH423EN
17
22
29
35
43
58
70
86
115
173
330
H
H
H
H
H
H
H
H
H
H
H
0.5
0.5
0.5
1.0
1.0
1.5
1.5
2.0
2.0
2.0
2.0
0.37
0.37
0.37
0.74
0.74
1.11
1.11
1.49
1.49
1.49
1.49
1.6/.8
1.6/.8
1.6/.8
3.2/1.6
3.2/1.6
4.2/2.1
4.2/2.1
5/2.5
5/2.5
5/2.5
5/2.5
913
833
679
1205
1023
1216
1068
1183
909
636
482
103
94
76
136
115
137
121
134
103
72
54
D or E
D or E
D or E
D
D
D
D
D
D
D
D

* At 60 Hz


CHART 18

90˚


  • Variable Frequency Drive, 6 - 60 Hz
  • NEMA 56 C Face for .5 Hp + 1 Hp
  • NEMA 145TC C Face for 1.5 + 2 Hp
  • Totally enclosed, Fan cooled
  • 230/460V, 3 phase
  • Order controller separately, See pages 114 & 115
Part Number RPM* Gearmotor Type Hp Kw FLA in-lbs N-m Vari-Speed
Control Chart
32M100HH423EN
32M080HH423EN
32M060HH423EN
32M050HH423EN
32M040HH423EN
32M030HH423EN
32M025HH423EN
32M020HH423EN
32M015HH423EN
32M010HH423EN
32M008HH423EN
17
22
29
35
43
58
70
86
115
173
330
H
H
H
H
H
H
H
H
H
H
H
0.5
0.5
0.5
1.0
1.0
1.5
1.5
2.0
2.0
2.0
2.0
0.37
0.37
0.37
0.74
0.74
1.11
1.11
1.49
1.49
1.49
1.49
1.6/.8
1.6/.8
1.6/.8
3.2/1.6
3.2/1.6
4.2/2.1
4.2/2.1
5/2.5
5/2.5
5/2.5
5/2.5
913
833
679
1205
1023
1216
1068
1183
909
636
482
103
94
76
136
115
137
121
134
103
72
54
D or E
D or E
D or E
D
D
D
D
D
D
D
D


CHART 19

90˚


  • Integrated motor control
  • Variable frequency drive, 10 to 80 Hz
  • Digital display with start/stop and forward/reverse keypad
  • NEMA 56C C Face
  • Totally enclosed, Fan cooled
  • 115/230V, 1 Phase input voltage
Part Number RPM* Gearmotor Type Hp Kw Controller Amps in-lbs N-m
32M100HH411EC
32M060HH411EC
32M040HH411EC
32M025HH411EC
32M020HH411EC
32M015HH411EC
17
29
43
70
86
115
H
H
H
H
H
H
0.5
0.5
1.0
1.0
1.0
1.0
0.37
0.37
0.74
0.74
0.74
0.74
12.4/6.2
12.4/6.2
12.4/6.2
12.4/6.2
12.4/6.2
12.4/6.2
656
488
735
512
425
326
74
55
83
57
48
36


CHART 20

90˚


  • Variable frequency drive, 25 - 63 Hz
  • Sealed Gearmotor
  • IEC 71 B5 C Face
  • IP 55 Protection Rating
  • Totally enclosed, Fan cooled
  • 230 Volts, 3 Phase
  • Order controller separately, See pages 114 & 115
Part Number RPM* Gearmotor Type 3 Phase N-m* Vari- Speed
Control Chart
Hp FLA
32Z100HH423EN 14 H 0.37 2.1 113 B

* At 50 Hz Note: When buying a gearmotor only without the starter, the customer must supply their
own on/off switch and motor overload protection to comply with the CE Safety Directive.

 


Notes:

  • LPZ Conveyors are not reversible
  • FLA = Full Load Amperes
  • Some motors & gear reducers may normally operate hot to the touch. Consult factory for specific operating temperatures.

 

  • IP 55 Protection Rating
  • Totally enclosed, Fan cooled
  • 230 Volts, 3 Phase
  • Order controller separately, See pages 114 & 115
  • Part Number RPM* Gearmotor Type 3 Phase N-m* Vari- Speed
    Control Chart Hp FLA 32Z100HH423EN 14 H 0.37 2.1 113 B * At 50 Hz Note: When buying a gearmotor only without the starter, the customer must supply their
    own on/off switch and motor overload protection to comply with the CE Safety Directive.

    Notes:

     

    Back to top